03 May 2018
Installation of new Classic Bond EPDM rubber cap sheet and black UPVC square line guttering, brackets, running outlet, stop ends, downpipe and off set bends plus new textured anti corrosion / U.V. coated aluminium flashings at the abutment wall and black ash UPVC trims fixed using ring shanked galvanised steel polytop nails. Preparing the flat [...]
30 Mar 2017
Re-pointing the failed mortar on the chimney stack flaunch, water table coping stones lifted, re-bedded & pointed and EPDM rubber roof completed with new white UPVC fascias & trims plus new black UPVC square line guttering, outlet, stop ends, corner union joint & brackets. Installation of polyethylene vapour barrier, 18mm OSB roof board and repairs [...]
04 Feb 2017
Outlet, gulley & flat roof clearance followed by repairs to the gulley & upstand. When this GRP (Glassfibre Reinforced Polyester) gulley was installed no glassfibre chopped strand netting was used to reinforce the polyester where the gulley meets the upstands at the parapet wall. Consequently without this reinforcement the polyester has failed and along with [...]